V0.2 (PVDF 0.2 µm) Sanitary Microfiltration Spiral-Wound Element


RECOMMENDED OPERATING PARAMETERS  
Pressure PSI BAR
Max. Inlet Pressure 120 8.3
Min. Outlet Pressure 10 0.7
Max. Pressure Drop per Element 18 1.2
Max. Permeate Backpressure 5 0.3
NOTE: Soft start on boost pumps required to minimize pressure/flow shocks to elements
Temperature Fahrenheit Celsius
Max. Continuous Operation 131° 55°
Max. CIP Temperature 122° 50°
     
pH Parameters pH
Operating Parameters At Max Temp. - 3-9
At Ambient Temp. - 2-10
Cleaning Parameters At Max Temp. - 2-11
At Ambient Temp. - 1.8-11